Encelto 200,000 To 440,000 Cells Intravitreal Implant
- 1 INDICATIONS AND USAGE
- 2 DOSAGE AND ADMINISTRATION
- 3 DOSAGE FORMS AND STRENGTHS
- 4 CONTRAINDICATIONS
- 5 WARNINGS AND PRECAUTIONS
- 6 ADVERSE REACTIONS
- 8 USE IN SPECIFIC POPULATIONS
- 11 DESCRIPTION
- 12 CLINICAL PHARMACOLOGY
- 13 NONCLINICAL TOXICOLOGY
- 14 CLINICAL STUDIES
- 16 HOW SUPPLIED/STORAGE AND HANDLING
- 17 PATIENT COUNSELING INFORMATION
- ENCELTO PRODUCT LABEL
- ENCELTO COREPACK LABEL
1 INDICATIONS AND USAGE
ENCELTO is indicated for the treatment of adults with idiopathic macular telangiectasia type 2 (MacTel).
2 DOSAGE AND ADMINISTRATION
2.1 Recommended Dose
For intravitreal implantation only
• ENCELTO is administered by a single surgical intravitreal procedure performed by a qualified ophthalmologist.
• The recommended dose is one ENCELTO implant per affected eye. Each ENCELTO implant contains 200,000 to 440,000 allogeneic retinal pigment epithelial cells expressing recombinant human ciliary neurotrophic factor (rhCNTF) (NTC-201-6A cell line), a neurotrophic factor.
2.2 ENCELTO Surgical Placement
The ENCELTO implant insertion is a surgical procedure performed in an operating room under aseptic conditions by a qualified ophthalmologist.
|
Pre-Surgical Preparation
Prepare the surgical field properly. |
|
|
Surgical Steps |
|
|
1. Preparing the Surgical Site a. Create a 7x7 mm peritomy of the conjunctiva and Tenon’s capsule at the selected implantation site. b. Place a corneal-limbal traction suture in the selected surgical quadrant (either inferotemporal or inferonasal) ( c. Maintain hemostasis of the underlying sclera and conjunctiva ( d. Using an MVR and 15-degree blade, create a 3.0 mm full-thickness sclerotomy 3.75 mm posterior and parallel to the limbus ( e. Confirm: • The incision is full thickness. • There is adequate hemostasis. • There is no spanning uveal tissue. |
|
|
2. Preparing the ENCELTO Implant a. Open the inner container and expose the upper compartment and luer lock cap ( b. Unlock the luer lock cap by turning it counterclockwise once. c. Lift the luer lock cap vertically to remove ENCELTO (attached to the gripper). d. Rinse ENCELTO with at least 5 mL of sterile Balanced Saline Solution (BSS). e. Keep ENCELTO moist by applying BSS every 10 minutes until insertion. f. While holding the luer lock cap, pass a double-armed 9-0 polypropylene suture needle through ENCELTO’s fixation loop ( |
|
|
3. Implantation of ENCELTO a. Gently open the sclerotomy incision and insert ENCELTO perpendicularly into the eye ( b. Ensure only the fixation loop is exposed. c. Release ENCELTO from the gripper by squeezing the indicated region with forceps or a fine needle holder ( |
|
|
4. Securing the Implant a. Secure ENCELTO by creating a 3-1-1 anchor knot with the polypropylene suture at the apex of the fixation loop ( b. Confirm ENCELTO is centered in the incision. c. Pass each suture arm centrally through either side of the wound at 90-99% scleral depth ( d. Pull up the suture ends and confirm that the fixation loop is at the proper depth (90-99%). e. Tie down the suture to the sclera with a 3-1-1 knot, ensuring the knot is placed away from the incision. f. If a suture breaks, leave the tail as long as possible and lay it flat. g. Take a 2.0 mm scleral bite at 50-75% depth beyond the sclerotomy on each side ( |
|
|
5. Closing the Incision a. Close the scleral incision with 9-0 nylon sutures (
b. Pull the polypropylene suture end taut and cut it flush to the sclera. c. Close the conjunctiva and Tenon’s capsule using 6-0 plain gut or chromic suture, or 7-0 Vicryl suture or similar. d. Ensure Tenon’s capsule covers the insertion site and use 3-point fixation and scleral bites. e. Administer sub-conjunctival steroid injection: dexamethasone, 2 mg/0.5 ml (4 mg/ml) or equivalent. If the case is complicated and inflammation is anticipated, a higher dose of dexamethasone (0.5 cc of 10 mg/ml) or equivalent may be used, at the surgeon’s discretion. f. Perform indirect ophthalmoscopy to confirm placement of ENCELTO in the vitreous and that there are no intraocular complications. Failure to perform indirect ophthalmoscopy can lead to unidentified malpositioning of ENCELTO and intraocular complications. |
|
|
Post-Operative Wound Care
|
|
Refer to ENCELTO Instructions for Use for detailed guidance on implantation procedure.
2.3 ENCELTO Removal Procedure
Removal of ENCELTO is a surgical procedure performed in an operating room under aseptic conditions by a qualified ophthalmologist. Remove ENCELTO implant, if vitrectomy with a complete gas fill or silicone oil fill is required or if infectious endophthalmitis occurs.
|
Surgical Steps |
|
|
1. Preparing the Surgical Site ( a. Create a 7x7 mm peritomy of the conjunctiva and Tenon’s capsule to expose the insertion site. b. c. Maintain hemostasis of the sclera and surrounding conjunctiva. |
|
|
2. Establishing Infusion & Vitrectomy ( a. Place an infusion cannula in the inferior quadrant (opposite ENCELTO). b. Confirm the infusion line is positioned within the vitreous cavity before opening the infusion. c. Insert two superior cannulas following normal pars plana vitrectomy protocol. d. Perform a thorough vitrectomy to remove vitreous surrounding ENCELTO without disrupting the hollow fiber membrane. |
|
|
3. Reopening the Sclerotomy a. Locate the ENCELTO incision and remove the two nylon sutures while leaving the polypropylene suture intact ( b. Using an MVR blade, carefully dissect open the original scleral incision down to the ENCELTO cap at the base of the fixation loop ( c. Extend the incision along the entire 3.0 mm length to full thickness. d. Cut the polypropylene anchor suture on the anterior side of the knot. e. Turn off or lower infusion pressure. |
|
|
4. Removing ENCELTO ( a. Fully open the pars plana sclerotomy and confirm there is no spanning uveal tissue. b. c. Cut off the remaining polypropylene knot. d. Remove ENCELTO from the eye. e. Inspect the ENCELTO capsule for any damage or penetration. f. Do not discard or dispose of the ENCELTO implant. Call and report to 1-833-963-9275. The appropriate action will be taken to initiate the return of ENCELTO and possible replacement. |
|
|
5. Closing the Incision a. Remove any prolapsed vitreous. b. Close the sclerotomy with interrupted 7-0 Vicryl sutures for a watertight closure. c. Remove the infusion line and additional cannulas. d. Close the conjunctiva with 6-0 plain gut sutures or equivalent. |
|
|
Post-Operative Wound Care
|
|
Refer to ENCELTO Instructions for Use for detailed guidance on removal procedure.
3 DOSAGE FORMS AND STRENGTHS
ENCELTO is a single-dose implant that contains 200,000 to 440,000 allogeneic retinal pigment epithelial cells expressing recombinant human ciliary neurotrophic factor (rhCNTF) (NTC-201-6A cell line) for intravitreal surgical placement. ENCELTO is an opaque semi-permeable capsule that is white to off-white, capped on both ends, and has a titanium loop on one end. The ENCELTO width is 1.2 ± 0.1 mm, its length is 6.1 ± 0.4 mm, and its internal diameter is 0.88 ± 0.02 mm (
4 CONTRAINDICATIONS
ENCELTO is contraindicated in patients with:
- Active or suspected ocular or periocular infections.
- Known hypersensitivity to Endothelial Serum Free Media (Endo-SFM)
5 WARNINGS AND PRECAUTIONS
5.1 Severe Vision Loss
Severe vision loss defined as three or more lines of visual acuity loss [≥15 Early Treatment Diabetic Retinopathy Study (ETDRS) letters] has occurred following ENCELTO implantation [see
5.2 Infectious Endophthalmitis
Infectious endophthalmitis may occur following ENCELTO implantation. Signs and symptoms of infectious endophthalmitis include progressively worsening eye pain, vision loss, or scleral and conjunctival injection. To mitigate the risk of endophthalmitis, use proper aseptic surgical technique for ENCELTO implantation [see
5.3 Retinal Tear and Detachment
Retinal tears and retinal detachment may occur following ENCELTO implantation. Signs and symptoms of retinal tears include acute onset of flashing lights, floaters, and/or loss of visual acuity. Signs and symptoms of retinal detachment may include progressive visual field loss and/or loss of visual acuity. Use standard vitreoretinal surgical techniques during ENCELTO implantation to minimize the risk of retinal tears and retinal detachment. Monitor for any signs or symptoms of retinal tear and/or retinal detachment. Treat rhegmatogenous retinal detachment and retinal tears promptly. Remove ENCELTO implant, if vitrectomy with a complete gas fill or silicone oil fill is required [see
5.4 Vitreous Hemorrhage
Vitreous hemorrhage, which may result in temporary vision loss, has occurred following ENCELTO implantation [see
5.5 Implant Extrusion
5.6 Cataract Formation
Cataract formation, including cataract cortical, cataract nuclear, cataract subcapsular, cataract traumatic, and lenticular opacities, has occurred following ENCELTO implantation [see
5.7 Suture Related Complications
Suture related complications, including conjunctival erosions due to suture tips and suture knots, have occurred following ENCELTO implantation [see
5.8 Delayed Dark Adaptation
Delayed Dark Adaptation, a delay in the ability to adjust vision from a bright lighting condition to a dim lighting, has occurred following ENCELTO administration which remained unchanged for the duration of study follow up [see
6 ADVERSE REACTIONS
6.1 Clinical Trials Experience
Because clinical trials are conducted under widely varying conditions, adverse reaction rates observed in the clinical trials of a drug cannot be directly compared to rates in the clinical trials of another drug and may not reflect the rates observed in practice.
The safety data described in this section reflects exposure to ENCELTO in two clinical trials, Study 1 (NTMT-03-A) and Study 2 (NTMT-03-B) and are pooled for analysis. A total of 117 patients received ENCELTO, and 111 patients underwent a sham procedure and were followed for a duration of 24 months [see
Serious adverse reactions occurred in six patients (5%) including suture related complications (n=5) and implant extrusion (n=1).
|
Adverse Reactions |
ENCELTO (N=117) n (%) |
Sham (N=111) n (%) |
|
Conjunctival hemorrhage |
36 (31) |
29 (26) |
|
Delayed dark adaptation |
27 (23.1) |
1 (1) |
|
Foreign body sensation in eyes |
18 (15) |
15 (13.5) |
|
Eye pain |
18 (15) |
10 (9) |
|
Suture related complication** |
18 (15.4) |
3 (2.7) |
|
Miosis |
18 (15.4) |
0 (0.0) |
|
Conjunctival hyperemia |
13 (11) |
9 (8) |
|
Eye pruritus |
10 (9) |
4 (3.6) |
|
Ocular discomfort |
10 (9) |
1 (1) |
|
Vitreous hemorrhage |
10 (8.5) |
0 (0.0) |
|
Vision blurred |
8 (7) |
4 (4) |
|
Headache |
8 (7) |
1 (1) |
|
Dry eye |
7 (6) |
2 (2) |
|
Eye irritation |
6 (5.1) |
2 (2) |
|
Cumulative cataract incidence |
6 (5) |
0 (0) |
|
Vitreous floaters |
6 (5) |
0 (0.0) |
|
Severe visual loss>15 letters*** |
4 (3) |
0 (0) |
|
Eye discharge |
4 (3.4) |
1 (0.9) |
|
Anterior chamber cell |
4 (3.4) |
0 (0.0) |
|
Iridocyclitis |
3 (2.6) |
0 (0) |
* Pooled data from Study 1 and Study 2; Adverse reaction rates were comparable between the two studies
**Suture related complications include exposed suture, foreign body sensation, conjunctival wound dehiscence, painful sutures, suture irritation, suture granuloma, scleral wound opening, and itchy suture
*** Includes one case of visual loss due to cataract formation which remained unresolved at the end of the study
8 USE IN SPECIFIC POPULATIONS
8.1 Pregnancy
Risk Summary
There are no data on the use of ENCELTO in pregnant women. Endogenous CNTF is naturally found in maternal plasma, placental cells, and umbilical cord blood. It is not known if the use of ENCELTO increases CNTF above naturally occurring levels in these tissues.
In animal reproduction studies, subcutaneous administration of rhCNTF to pregnant rats and rabbits demonstrated no evidence of teratogenic effects on the fetus. However, when administered to rabbits at a dose level of 10ug/kg/day, a decrease in implantations and live fetuses was observed. When administered to rats at a dose level of 100ug/kg/day a decrease in corpora lutea was observed.
The estimated background risk of major birth defects and miscarriage in the indicated population is unknown. All pregnancies have a background risk of birth defect, loss, or other adverse outcomes. In the U.S. general population, the estimated background risk of major birth defects is 2% to 4% and of miscarriage is 15% to 20% of clinically recognized pregnancies.
Data
Animal Data
See Risk Summary for details on data.
8.2 Lactation
Risk Summary
There is no data on the presence of ENCELTO in human milk, its effects on the breastfed infant, or its impact on milk production.
The developmental and health benefits of breastfeeding should be considered along with the mother's clinical need for ENCELTO and any potential adverse effects on the breastfed infant from rhCNTF or from the underlying maternal condition.
8.4 Pediatric Use
The safety and effectiveness of ENCELTO have not been established in pediatric patients.
8.5 Geriatric Use
There were 38 patients (32%) 65 years of age and older and two patients (1%) 75 years of age and older in Study 1 and Study 2 who received ENCELTO [see
11 DESCRIPTION
ENCELTO (revakinagene taroretcel-lwey) implant, is single-dose, sterile, nonpyrogenic and retrievable.
ENCELTO is an allogeneic encapsulated cell-based gene therapy that contains 200,000 to 440,000 allogeneic retinal pigment epithelial cells expressing recombinant human ciliary neurotrophic factor (rhCNTF) (NTC-201-6A cell line) for surgical intravitreal placement.
ENCELTO consists of an opaque, semi-permeable white to off-white capsule surrounding a scaffold of polyethylene terephthalate (PET) yarn, loaded with rhCNTF secreting allogeneic retinal pigment epithelial cells (NTC-201-6A cell line). Each end of the semi-permeable capsule is sealed with medical grade methacrylate adhesive, and to one end a titanium fixation loop is attached. ENCELTO width is 1.2 ± 0.1 mm, length is 6.1 ± 0.4 mm, and its internal diameter is 0.88 ± 0.02 mm (
ENCELTO is packaged in a protective inner container within an orange to pink liquid hold medium referred to as Endothelial Serum Free Media (Endo-SFM), which is maintained sterile by a sealed outer container. ENCELTO is provided attached, by the fixation loop, to a gripper that both suspends ENCELTO in the Endo-SFM and facilitates intraocular insertion. The Endo-SFM within the packaging inner container may contain visible particles generally described as fiber, solid, white, or metallic in appearance.
ENCELTO is manufactured using animal and human derived reagents.
12 CLINICAL PHARMACOLOGY
12.1 Mechanism of Action
ENCELTO secretes recombinant human ciliary neurotrophic factor (rhCNTF), which is one of several neurotrophic factors endogenously produced by neurons and supporting glial cells. Exogenous CNTF is thought to initially target Müller glia to trigger a cascade of signaling events that may promote photoreceptor survival; however, the mechanism of action for ENCELTO is not completely understood.
12.3 Pharmacokinetics
Systemic exposure of rhCNTF was measured in 2 distribution studies in rabbits and in 2 toxicology studies in minipigs. Overall, there was no evidence of systemic exposure to rhCNTF after implantation of ENCELTO in rabbits for periods up to 9 months or in minipigs for periods of up to 6 months.
Following intraocular implantation of a single ENCELTO dose in rabbits at 12 weeks, the mean Cmax of rhCNTF in the vitreous and aqueous was 2.0 and 0.3 ng/mL, respectively, and below the level of quantitation (LLOQ) in the serum and contralateral, untreated eye. Similarly in human patients, rhCNTF levels were below the limit for LLOQ in the serum.
12.6 Immunogenicity
The observed incidence of anti-drug antibodies is highly dependent on the sensitivity and specificity of the assay. Differences in assay methods preclude meaningful comparisons of the incidence of anti-drug antibodies in the studies described below with the incidence of anti-drug antibodies in other studies, including those of ENCELTO or of other products.
In a six-month Study NTMT-02B in which patients received ENCELTO in a single eye, one out of 31 patients (3%) tested positive for serum antibodies against the ENCELTO secreted product protein rhCNTF and one patient (3%) tested positive to serum non-secreted intracellular protein DHFR.
Because of the low occurrence of anti-drug antibodies, the effect of serum anti-rhCNTF and anti-DHFR antibodies on the safety or efficacy of ENCELTO is unknown.
13 NONCLINICAL TOXICOLOGY
13.1 Carcinogenesis, Mutagenesis, Impairment of Fertility
Carcinogenesis and Mutagenesis
No carcinogenicity or mutagenicity studies have been conducted with rhCNTF.
Impairment of Fertility
In male rats, fertility was unaffected at subcutaneous doses of rhCNTF up to 300 μg/kg/day.
See
14 CLINICAL STUDIES
Study 1 was a randomized, multi-center, sham-controlled study which enrolled adults with MacTel. For enrollment, the patients were required to have a photoreceptor inner segment/outer segment (IS/OS PR) break (loss) in ellipsoid zone (EZ) between 0.16 and 2.00 mm2 measured by spectral domain-optical coherence tomography (SD-OCT) and best corrected visual acuity (BCVA) of 54-letter score or better (20/80 or better) as measured by the Early Treatment Diabetic Retinopathy Study (ETDRS) chart at screening. Patients with neovascular MacTel were excluded. Patients were randomized to receive either ENCELTO intravitreal implant or sham procedure under standard operative procedures. Patients in ENCELTO group underwent conjunctival peritomy, implant placement in the vitreous cavity via sclerotomy and closure with sutures. Patients in the Sham group underwent conjunctival peritomy, scleral pressure, and conjunctival closure with sutures. One hundred and fifteen (96%) of 120 patients underwent the assigned procedure and were included in the analysis of efficacy.
|
Efficacy endpoints |
ENCELTO n= 58 |
Sham n=57 |
Difference ENCELTO-Sham |
P-valuec |
|
Rate of change in EZ area loss from baseline over 24 monthsa mm2 (95% CI) |
0.075 (0.05, 0.10) |
0.166 (0.14, 0.19) |
-0.091 (-0.13, -0.06) |
<0.0001 |
|
Mean change in aggregate retinal sensitivity loss from baseline to 24-monthsb dB (95% CI) |
25.27 (15.88, 34.67) |
43.02 (31.78, 54.26) |
-17.75 (-32.58, -2.91) |
0.02 |
|
Efficacy endpoints |
ENCELTO n= 59 |
Sham n=54 |
Difference ENCELTO-Sham |
P-valuec |
|
Rate of change in EZ area loss from baseline over 24 monthsa mm2 (95% CI) |
0.111 (0.08, 0.14) |
0.160 (0.13, 0.19) |
-0.049 (-0.089, -0.008) |
0.0186c |
|
Mean change in aggregate retinal sensitivity loss from baseline to 24-monthb dB (95% CI) |
40.02 (26.08, 53.96) |
41.97 (30.34, 53.60) |
-1.95 (-20.33, 16.43) |
0.83 |
CI = confidence interval, EZ=ellipsoid zone
a Estimated by using a longitudinal mixed model including EZ area loss as the dependent variable, patient-specific random intercepts, treatment group, time (continuous), and interaction between treatment and time as covariates. The baseline and Months 12, 16, 20, and 24 visits were included.
b Estimated by using two-sample t-test; Seven ENCELTO and six Sham patients were excluded due to missing data.
c Statistically significant at two-sided alpha of 0.05.
16 HOW SUPPLIED/STORAGE AND HANDLING
16.1 How Supplied
ENCELTO is supplied as a sterile, single-dose, implant that contains 200,000 to 440,000 allogeneic retinal pigment epithelial cells expressing rhCNTF (NTC-201-6A cell line).
ENCELTO is packaged in a protective inner container within an Endothelial Serum Free Media (Endo-SFM), which is maintained sterile by a sealed outer container. ENCELTO is provided attached to a gripper that both suspends ENCELTO in the Endo-SFM and facilitates intraocular insertion. ENCELTO contains no preservatives.
NDC: 82958-501-01
See
|
Components |
Description |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Figure 16. ENCELTO Corepack Contents
Figure 17. ENCELTO
Figure 18. ENCELTO Inner Container
Figure 19. pH Color Guide
16.2 Storage and Handling
17 PATIENT COUNSELING INFORMATION
Advise the patient to read the FDA-approved patient labeling (Patient Information).
Discuss the following with the patient.
Advise patients that ENCELTO implantation may be associated with infectious endophthalmitis (eye infection), retinal tear and detachment (retina separates from the eye wall resulting in vision loss), vitreous hemorrhage (bleeding within the central cavity of the eye), implant extrusion, suture-related complications, cataract formation (clouding of the lens of the eye), severe vision loss, and delayed dark adaptation (ability of the eye to adjust from bright lighting conditions to dark lighting conditions) [see
Instruct patients to seek immediate care from an ophthalmologist if they experience any signs or symptoms that could be associated with these events which may include the following:
- An increase in floaters, the appearance of “spider webs”, flashing lights, sensitivity to light, or loss of vision or visual field;
- Increasing eye pain, progressive redness in the white of the eye, a sudden sensation that something is in their eye (i.e., foreign body sensation) or eye discharge.
Advise patients that they may temporarily experience the following after ENCELTO implantation:
- Mild sensation of something in the eye (i.e., foreign body sensation)
- Eye redness, irritation, pain or discomfort, or dryness
- Blurred vision or floaters
Advise patients that delayed dark adaptation may be experienced for the length of time that ENCELTO is surgically placed [see
- Driving: delayed dark adaptation may impair one's ability to see objects, pedestrians, or road signs when moving rapidly from a brightly lit environment to a dimly lit environment (for example, entering a tunnel during the daytime).
- Navigating in the dark: Advise caution when moving from bright to dark areas, such as entering a dark room or stepping outside at dusk. Consider using flashlights, nightlights, or motion-activated lighting at home.
- Consider wearing sunglasses or tinted lenses in bright environments to reduce the impact of transitioning from light to dark.
Magnetic Resonance (MR) Conditional Information
ENCELTO is MR conditional. Advise patients that they have ENCELTO implanted in their eye and provide the patient with their implant card should they require Magnetic Resonance Imaging (MRI).
Driving and Using Machines
- Advise patients to not drive or use machinery until the eye shield has been removed and their ophthalmologist informs them that their vision has recovered to an acceptable level.
Postoperative Care
Advise patients on the following post operative care:
- Avoid heavy lifting (over 20 pounds) for one week.
- Keep water out of the eye (e.g., close eye while showering) for one week.
- Protect eyes by wearing glasses or protective eyewear during the day and using an eye shield at night for one week.
- Use a topical antibiotic solution at a frequency of 1 drop four times a day for 7 days.
- Use a steroid drop taper of prednisolone acetate 1% (or equivalent) starting the day after surgery with the following taper:
- 1 drop four times a day for the first 7 days;
- 1 drop three times a day for the next 7 days;
- 1 drop two times a day for the next 7 days;
- 1 drop once a day for the last 7 days.
Neurotech Pharmaceuticals, Inc.
Building 1, Suite 101
Cumberland, RI 02864
U.S. license number: 2321
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Manufactured for: Treatment of idiopathic macular telangiectasia type 2 (MacTel) Manufactured by: |
This Patient Information has been approved by the U.S. Food and Drug Administration. F11002F Rev. 01
Revised: 2025/03
Instructions for Use
ENCELTO PRODUCT LABEL
ENCELTO COREPACK LABEL